Robotis Dynamixel DX-116 Manuel d'utilisateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
28
English Translation by: Tribotix Pty Ltd
www.tribotix.com
DYNAMIXEL
DX-116
Instruction Packet Instruction = WRITE_DATA, Address = 0x2F, DATA = 0x01
Communication ->[Dynamixel]:FF FF 00 04 03 2F 01
C8 (LEN:008)
<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)
Status Packet Result NO ERROR
If Locked, it can only be unlocked by removing power.
If trying to access other data areas whilst locked, an error will be returned.
->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)
<-[Dynamixel]:FF FF 00 02 08 F5 (LEN:006)
Example 20 Set the minimum punch (output) in the Dynamixel with ID=0 to 0x40.
Instruction Packet Instruction = WRITE_DATA, Address = 0x30, DATA = 0x40, 0x00
Communication ->[Dynamixel]:FF FF 00 05 03 30 40 00
87 (LEN:009)
<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)
Status Packet Result NO ERROR
Range Error